[2026-04-12 06:14:02] INFO boot: NestThermo-7 v4.2.18 starting [2026-04-12 06:14:03] INFO wifi: associated SSID=HomeNet-5G rssi=-58 [2026-04-12 06:14:04] INFO mqtt: connected broker=cloud.nestthermo.example [2026-04-12 06:14:05] INFO sched: loaded 6 schedules, next=06:30 set=21C [2026-04-12 06:30:01] INFO hvac: heat on, target=21.0C measured=18.4C [2026-04-12 06:38:22] WARN WARN_OVERHEAT zone=A coil_temp=78C threshold=72C [2026-04-12 06:38:22] INFO hvac: throttling fan to 60% [2026-04-12 06:41:08] WARN WARN_OVERHEAT zone=A coil_temp=81C threshold=72C [2026-04-12 06:41:09] ERROR ERR_42 zone=A code=THERMAL_SAFETY_TRIP, cutting power to coil [2026-04-12 06:41:09] INFO hvac: heat off (safety trip) [2026-04-12 06:41:10] INFO mqtt: publish state=tripped reason=thermal [2026-04-12 06:42:00] INFO user_action: app reset_trip received from user_id=primary [2026-04-12 06:42:01] INFO hvac: heat on, target=21.0C measured=18.9C [2026-04-12 06:49:55] WARN WARN_OVERHEAT zone=A coil_temp=79C threshold=72C [2026-04-12 06:51:22] ERROR ERR_42 zone=A code=THERMAL_SAFETY_TRIP, cutting power to coil [2026-04-12 06:51:22] INFO hvac: heat off (safety trip) [2026-04-12 06:51:23] WARN WARN_AIRFLOW return_air_dp=0.04kPa expected>=0.12kPa [2026-04-12 06:51:23] HINT airflow below expected — check return filter / vent blockage [2026-04-12 07:02:00] INFO user_action: app reset_trip received from user_id=primary [2026-04-12 07:02:01] INFO hvac: heat on, target=21.0C measured=18.7C [2026-04-12 07:09:14] WARN WARN_OVERHEAT zone=A coil_temp=80C threshold=72C [2026-04-12 07:10:48] ERROR ERR_42 zone=A code=THERMAL_SAFETY_TRIP, cutting power to coil [2026-04-12 07:10:48] WARN WARN_AIRFLOW return_air_dp=0.03kPa expected>=0.12kPa [2026-04-12 07:10:48] ERROR ERR_PERSISTENT_FAULT 3 trips in 30min — entering lockout [2026-04-12 07:10:49] INFO mqtt: publish state=lockout reason=persistent_overheat [2026-04-12 07:10:49] INFO display: showing fault code F-42 to user [2026-04-12 07:11:02] INFO user_action: app reset_trip received — IGNORED (in lockout) [2026-04-12 07:30:00] INFO hb: heartbeat [2026-04-12 08:00:00] INFO hb: heartbeat [2026-04-12 09:14:30] INFO user_action: power_cycle detected [2026-04-12 09:14:31] INFO boot: NestThermo-7 v4.2.18 starting